ToxiRAE II
ToxiRAE 3


QRAE II - Diffusion
QRAE II - w/Pump
QRAE
QRAE Plus
VRAE

EntryRAE
MultiRAE Plus
MultiRAE Plus-Wing Tank Entry Kit
SentryRAE
AreaRAE
AreaRAE Steel

MiniRAE Lite
MiniRAE 3000
ppbRAE 3000
UltraRAE 3000
MiniRAE 2000
ppbRAE Plus
UltraRAE
ToxiRAE Plus

AreaRAE
AreaRAE Steel
AreaRAE Gamma
MultiRAE Plus
MiniRAE 3000
ppbRAE 3000
UltraRAE 3000

AutoRAE Lite-ToxiRAE 3
AutoRAE Lite-QRAE II
AutoRAE

    RAE Radiation Monitors
GammaRAE II R
AreaRAE Gamma

    RAE Fixed Gas Detection
RAEGuard LEL
RAEGuard EC
RAEGuard PID

    RAE Detector Tubes Pumps
Colorimetric Detection Tubes
Piston Hand Pump

HazRAE
PlumeRAE
Safer Homeland Responder

    RAE Parts and Accessories

 


Authorize.net Verified
 
 

 

 

 

 
 
UltraRAE 3000 UltraRAE 3000
Unit of Measure: Each
Please use dropdown box(s) above to configure your monitor.
Quantity:

RAE Systems- UltraRAE 3000 Specific Compound Monitor for VOC, Benzene and Butadiene Gas Detection.

The RAE UltraRAE 3000 is the most advanced Compound-Specific Monitor on the market. Its Photoionization Detector’s (PID) extended range of 0.05 to 10,000 ppm in VOC mode and 50 ppb to 200 ppm in benzene-specific mode makes it an ideal instrument for applications from entry pre-screening during refinery and plant maintenance to hazardous material response, marine spill response and refinery down-stream monitoring.

*Note- If choosing the 9.8eV Lamp; a pack of 10 RAE SEP Tubes is included. Specify either Benzene or Butadiene upon the 9.8ev Lamp option.

UltraRAE 3000 Monitor only includes:
- UltraRAE 3000 Monitor
- RAE UV Lamp, SEP Tubes as specified
- Red Rubber boot
- Alkaline battery adapter
- Lamp Cleaning Kit
- Datalogging with ProRAE Studio Package
- Flex-I-Probe and short probe
- Exernal Filter
- Tool Kit
- Travel Charger
- Training CD ROM
- Soft Leather carry case
-*Lithium-Ion Rechargeable Battery, Universal AC/DC adapter and universal plug kit
-*Wireless Bluetooth Communication (to use with RAELink 3,ProRAE Remote)

* If specified on configuration.

UltraRAE 3000 Monitor with Accessories Kit adds:
- Hard transport case wiht pre-cut foam
- Charging Download Cradle (instead of travel charger)
- Organic Vapor zeroing kit
- Gas Outlet port adapter and tubing
- 5 Porous metal filters and O-Rings

UltraRAE 3000 Optional Calibration Kit with Accessory Kit adds:
- Accessories Kit
- Calibration gas cylinder(s) (as specified either 29 Liter Cylinder for Benzene or 34 Liter Cylinder for Isobutylene)
- Calibration Regulator (thread depending on cylinder size) & Flow Controller

*Hazmat Shipping fee is included on Calibration Kits. Standard Shipping rates will apply.

*Note Please choose correct Lamp for your needs:
- 9.8 eV 1/2" Lamp for Benzene ( comes with 10 each RAE SEP Benzene Tubes )
- 9.8 eV 1/2" Lamp for Butadiene ( comes with 10each RAE SEP Butadiene Tubes )
- 10.6 eV 1/2" Lamp for Total VOC mode only
- 11.7 eV 1/2" Lamp for Total VOC mode only

UltraRAE 3000 - Datasheet

Interchangeable RAE-SepTM Filter Tubes:
CAUTION: RAE-SepTM tubes were designed for use in RAE Systems instruments only. Use in any other manufacturer's equipment may give inaccurate results.



Benzene SEP Tubes - Datasheet

Butadiene SEP Tubes Polymer manufacture - Datasheet

VOC- For continuous PID measurement.


Key Features:

Superior Performance

  Proven PID technology
  3-second response in VOC mode or 60 seconds in compound-specific mode
  • Extended range up to 10,000 ppm (in VOC mode) with improved linearity
  • Humidity compensation with built-in humidity sensor
  • Automatic temperature-controlled sampling time calculation
  • Detects benzene down to 50 ppb (0.05 ppm)
  Unique 15-minute benzene STEL calculation with 15-minute real-time benzene-specific measurement and recording
  Highly specific readings, combining a 9.8eV UV lamp and RAE-Sep™ benzene tube
  New sampling probe design provides instant tube-breakthrough visibility
Extremely Versatile
  VOC mode or Benzene-Specific mode for extreme versatility
  Real-time wireless data transmission with built-in Bluetooth and optional RAELink3 portable modem
  Integrated RAE Systems Correction Factors list for more than 200 compounds, measuring more compounds than any other PID
  Field-interchangeable battery pack is replaceable in seconds without tools
Easy to Use
  Large graphic display
  Multi-language support
  Easy access to lamp and sensor in seconds without tools
Low Cost of Ownership
  Inexpensive analysis using low-cost RAE-Sep tubes vs. gas detection tubes
  Much less expensive than a portable GC, and no annual factory calibration is required

Applications
  Confined space entry pre-screening during refinery and plant maintenance
  Hazardous material response
  Marine spill response
  Refinery down-stream monitoring



May we also suggest
RAE-SEP Tubes for UltraRAE Monitors
RAE-SEP Tubes for UltraRAE Monitors
Benzene Calibration Gas for RAE Systems Monitors
Benzene Calibration Gas for RAE Systems Monitors
Isobutylene 100ppm Calibration Gas for RAE Systems Monitors
Isobutylene 100ppm Calibration Gas for RAE Systems Monitors
Butadiene Calibration Gas for RAE Systems Monitors
Butadiene Calibration Gas for RAE Systems Monitors



 
Powered by:         
InfuseWeb Hosting   
 
 
Site Map Northside Sales Co.