ToxiRAE II
ToxiRAE 3
ToxiRAE Pro
ToxiRAE Pro LEL
ToxiRAE Pro PID


QRAE II - Diffusion
QRAE II - w/Pump
QRAE
QRAE Plus
VRAE
MultiRAE Lite

EntryRAE
MultiRAE Lite
MultiRAE
MultiRAE Pro
MultiRAE Plus
SentryRAE
AreaRAE
AreaRAE Steel

MiniRAE Lite
MiniRAE 3000
ppbRAE 3000
UltraRAE 3000
MiniRAE 2000
ppbRAE Plus
UltraRAE
ToxiRAE Plus
ToxiRAE Pro PID

AreaRAE
AreaRAE Steel
AreaRAE Gamma
MultiRAE
MultiRAE Pro
MultiRAE Plus
MiniRAE 3000
ppbRAE 3000
UltraRAE 3000

AutoRAE Lite-ToxiRAE 3
AutoRAE Lite-QRAE II
AutoRAE

    RAE Radiation Monitors
GammaRAE II R
AreaRAE Gamma
DoseRAE 2
MultiRAE Pro

    RAE Fixed Gas Detection
RAEGuard LEL
RAEGuard EC
RAEGuard PID
MeshGuard

    RAE Detector Tubes Pumps
Colorimetric Detection Tubes
Piston Hand Pump

HazRAE
PlumeRAE
Safer Homeland Responder

   RAE Parts and Accessories

 


Authorize.net Verified
 
 

 

 

 

 
 
Humidity Filtering II Tube Humidity Filtering II Tube
Quantity:

Humidity Filtering II Tube.

The Humidity Filtering II Tube dries the sample gas entering pumped instruments. It is particularly suited for removing humidity effects on photoionization detectors (PIDs) while making VOC measurements, and typically lasts for about a half hour of continuous readings.

The Humidity Filtering II Tube utilizes a solid adsorbent to remove moisture without impacting the detection and measurement of most VOCs.

Options:

Adapter for Flex-I-Probe - Each

Humidity Filtering II Tubes - 10 per box


Key Features:

 

  • Enables continuous reading of VOCs under extremely humid conditions for about one half hour (per tube) at room temperature.
  • Prevents drifting readings at high humidity when the sensor is dirty. Extends the time needed between sensor cleanings.
  • Attaches to the Flex-I-Probe inlet with the same adapter used for ppbRAE VOC zeroing tubes.
  • Especially useful for measuring chlorinated solvents and fuels under high humidity conditions as are often encountered during soil and water remediation.
  • Can be used with other instruments having a built-in pump such as ppbRAE, UltraRAE, MultiRAE, and VRAE when humidity is an issue, such as PID or low-level LEL sensor measurements. (See TN-178 [below] for adapter connections or for further details.) 



    Downloads:

    • Humidity Filtering II Data Sheet


    Technical Notes:

    • TN-178: Humidity Filtering II Tube for PID Measurements in Humid Environments

      * Caution: Absorbs some compounds like ammonia and slows the response of heavy compounds, especially at low concentrations or low temperatures.

 



 